AN800 central unit for 1-4 Boilers
The central unit AN800 is the main device of the fixed fume analysis system which manages signals coming from the peripheral probes installed at boilers (max. 4). The central unit is housed in a polypropylene case with trans… See more...
The central unit AN800 is the main device of the fixed fume analysis system which manages signals coming from the peripheral probes installed at boilers (max. 4).
The central unit is housed in a polypropylene case with transparent polycarbonate door and rating IP65.
Main card includes a 16-bit microcontroller which processes all the input data, displays them and stores them in an 16Mb Flash store.
The communication through Modbus Rtu binary protocol is done by a remote RS232 or RS485 output.
The boiler status reading is done every seconds.
Standard Specifications
Power supply: 230Vca 50-60HZ (+10-15%)
Absorption: 35 VA max a 230Vac
Passive analog inputs 4-20mA: max 4 for each boiler
Active analog inputs 4-20mA: max 4 for each boiler
Consent inputs (n° 2 for each boiler): Normally Closed contact
N.3 general relays: 3A 230Vca
Work temperature and humidity: da +5° a + 45°C / da 15 a 95%
To view the video, you need to accept our Cookie Policy. If the player doesn't appear, click the link below.
AN800 central unit for 1-4 Boilers
/images/zoo/FRONTALE_logo_VERDE.jpg
<p>The central unit AN800 is the main device of the fixed fume analysis system which manages signals coming from the peripheral probes installed at boilers (max. 4).<br />The central unit is housed in a polypropylene case with transparent polycarbonate door and rating IP65.<br />Main card includes a 16-bit microcontroller which processes all the input data, displays them and stores them in an 16Mb Flash store.</p>
<p>The communication through Modbus Rtu binary protocol is done by a remote RS232 or RS485 output.<br />The boiler status reading is done every seconds.</p>
<p><img src="images/Gallerie/AN750/AN750dis.jpg" alt="" width="100%" height="NaN" /></p>
Control unit
// Code example
<div id="myid" class="myclass" hidden>
Lorem ipsum <strong>dolor</strong> sit amet, consectetur adipiscing elit.
</div>
Releated Products
Do you need further informations?
Get in touch with us
If you have not found the product or service you want, or if you need a tailor-made project contact us now! We are happy to help.
Contact Us