GAS GAS solenoid valves are designed to be paired with any gas or carbon monoxide detection system that, in the event of an alarm, sends a signal to shut off the main gas supply.
Made of aluminium and certified PED (CE 0496 / CE 0497), they comply with the CEI UNI EN 50194 standard for gas detection systems.
They are installed on the supply pipe, after a filter, outside the monitored environment, and upstream of the regulation components. Installation must follow the direction indicated by the arrow engraved on the valve body.
In the event of danger detected by the sensor or control device, the valve automatically shuts off the gas flow. Manual reset is required: this is done by pulling the knob upward or, depending on the model, pressing the reset device axially after unscrewing the protective cap (which must be re-tightened after the operation).
Their simple and safe operation ensures high reliability.
Gas Solenoid Valves N.O. up toDN100
/images/zoo/VALVOLA_GAS_100_800x800.jpg
<p data-start="1299" data-end="1481"><strong data-start="1299" data-end="1326">GAS GAS solenoid valves</strong> are designed to be paired with any gas or carbon monoxide detection system that, in the event of an alarm, sends a signal to shut off the main gas supply.</p>
<p data-start="1483" data-end="1862">Made of aluminium and <strong data-start="1505" data-end="1542">certified PED (CE 0496 / CE 0497)</strong>, they comply with the <strong data-start="1565" data-end="1585">CEI UNI EN 50194</strong> standard for gas detection systems.<br data-start="1621" data-end="1624" /> They are installed on the supply pipe, <strong data-start="1663" data-end="1681">after a filter</strong>, <strong data-start="1683" data-end="1720">outside the monitored environment</strong>, and <strong data-start="1726" data-end="1767">upstream of the regulation components</strong>. Installation must follow the direction indicated by the <strong data-start="1825" data-end="1861">arrow engraved on the valve body</strong>.</p>
<p data-start="1864" data-end="2266">In the event of danger detected by the sensor or control device, the valve <strong data-start="1939" data-end="1979">automatically shuts off the gas flow</strong>. <strong data-start="1981" data-end="1997">Manual reset</strong> is required: this is done by <strong data-start="2027" data-end="2054">pulling the knob upward</strong> or, depending on the model, <strong data-start="2083" data-end="2120">pressing the reset device axially</strong> after unscrewing the protective cap (which must be re-tightened after the operation).<br data-start="2206" data-end="2209" /> Their simple and safe operation ensures high reliability.</p>