Produced by:
via Miglioli, 47 - 20054 Segrate (MI), Italy
Tel.+39 02 26922890
2039
TS593 Industrial gas detector, with display
The new TS593 with display is the last industrial gas detector born in the TECNOCONTROL production.
The function of the display is very important as thanks to it, the operator can visualize the gas concentration in the installation aerea in real time, having an
immediate perception of the risk level, increasing significantly his safety.
A magnetic key may activate some control points allowing a non-intrusive calibration: this is the best solution in high- risk of explosion places as in this way
maintenance can be done without opening the sensor. Calibration and zero may be effected easly and in total safety on the outiside.
The new explosion -proof cases line is ATEX CESI 03 ATEX 323X certified, II 2 G Ex db IIC T6 Gb, according to EN60079-O, EN60079-1, IP65 protection level.
- Archievable for Flammable gases, Toxic and Oxygen
- Can be equipped with sensible element: Pellistor, Electrochemical, Infrared
- Available with 4-20mA output
- Backlight LCD display
- Gas concentration reading in real time
- Calibration and zero non-intrusive with magnetic pen
- Auto get zero drift
All models are equipped with:
- Replaceable cartridge sensor
- Pre-calibrated cartridges
- Automatic Zero in air simplified using “F1” and “F2” keys
- Automatic calibration simplified by “F1” ed “F2” keys
- Made with 3 microprocessors
- Polarized terminals
- Housing II 2 G Ex db IIC T6 Gb
- Certification CESI 03 ATEX 323 X
- Ex marking : II 2 G Ex db IIC T6 Gb
- No. 1 linear 4÷20 mA current output
- Terminals plug-in type
TS593 Industrial gas detector, with display
images/zoo/TS593_atex.png
<p style="text-align: justify;">The new TS593 with display is the last industrial gas detector born in the TECNOCONTROL production.</p>
<p style="text-align: justify;">The function of the display is very important as thanks to it, the operator can visualize the gas concentration in the installation aerea in real time, having an</p>
<p style="text-align: justify;">immediate perception of the risk level, increasing significantly his safety.</p>
<p style="text-align: justify;">A magnetic key may activate some control points allowing a non-intrusive calibration: this is the best solution in high- risk of explosion places as in this way</p>
<p style="text-align: justify;">maintenance can be done without opening the sensor. Calibration and zero may be effected easly and in total safety on the outiside.</p>
<p style="text-align: justify;">The new explosion -proof cases line is ATEX CESI 03 ATEX 323X certified, II 2 G Ex db IIC T6 Gb, according to EN60079-O, EN60079-1, IP65 protection level.</p>
<ul>
<li style="text-align: justify;">Archievable for Flammable gases, Toxic and Oxygen</li>
<li style="text-align: justify;">Can be equipped with sensible element: Pellistor, Electrochemical, Infrared</li>
<li style="text-align: justify;">Available with 4-20mA output</li>
<li style="text-align: justify;">Backlight LCD display</li>
<li style="text-align: justify;">Gas concentration reading in real time</li>
<li style="text-align: justify;">Calibration and zero non-intrusive with magnetic pen</li>
<li style="text-align: justify;">Auto get zero drift </li>
</ul>
<p>All models are equipped with:</p>
<ul>
<li>Replaceable cartridge sensor</li>
<li>Pre-calibrated cartridges</li>
<li>Automatic Zero in air simplified using “F1” and “F2” keys</li>
<li>Automatic calibration simplified by “F1” ed “F2” keys</li>
<li>Made with 3 microprocessors</li>
<li>Polarized terminals</li>
<li>Housing II 2 G Ex db IIC T6 Gb</li>
<li>Certification CESI 03 ATEX 323 X</li>
<li>Ex marking : II 2 G Ex db IIC T6 Gb</li>
<li>No. 1 linear 4÷20 mA current output</li>
<li>Terminals plug-in type</li>
</ul>
<p><br /><img src="images/zoo/ts293-schema.jpg" alt="" width="50%" height="NaN" /></p>
<p> </p>
Industrial gas detectors
// Code example
<div id="myid" class="myclass" hidden>
Lorem ipsum <strong>dolor</strong> sit amet, consectetur adipiscing elit.
</div>
Type | Sensors | Gas | cylinder | Average Time | Cartridge | Maximun storage time | measuring range |
---|---|---|---|---|---|---|---|
TS593PXH | Pellistor | CH4 | BO200 | 5 | ZSK02/EX | 5 mesi/months | 0÷20% LEL |
TS593PXH | Pellistor | GPL | BO200 | 5 | ZSK02/EX | 5 mesi/months | 0÷20% LEL |
TS593PXH | Pellistor | H2 | BO200 | 5 | ZSK02/EX | 5 mesi/months | 0÷20% LEL |
TS593PXH | Pellistor | Benzina/Petrol | BO200 | 5 | ZSK04/EX | 5 mesi/months | 0÷20% LEL |
TS593EA | Electrochemical | NH3 | on request | 3 | ZSEA1/EX | 5 mesi/months | 0÷300 ppm |
TS593ECS | Electrochemical | CO | BO210 | 2 | ZSEC1/EX | 1 mesi/months | 0÷300 ppm |
TS593ECH | Electrochemical | CO | BO210 | 2 | ZSEC2/EX | 3 mesi/months | 0÷300 ppm |
TS593EH | Electrochemical | H2S | BO009 | 2 | ZSEH1/EX | 3 mesi/months | 0÷100 ppm |
TS593EHCN | Electrochemical | HCN | BO016 | 2 | ZSEH1/EX | 3 mesi/months | 0÷100 ppm |
TS593PXH | Pellistor | HCN | BO009 | 2 | ZSEN1/EX | 3 mesi/months | 0÷100 ppm |
TS593EN2 | Electrochemical | NO2 | on request | 2 | ZSEN2/EX | 3 mesi/months | 0÷30 ppm |
TS593E0 | Electrochemical | O2 | on request | 2 | ZSEO1/EX | 3 mesi/months | 0÷25% Vol |
TS593ES | Electrochemical | SO2 | on request | 2 | ZSES1/EX | 3 mesi/months | 0÷20 ppm |
TS593EHCL | Electrochemical | HCL | on request | 2 | ZSEHCL/EX | 3 mesi/months | 0÷30 ppm |
TS593IC2-H | Infrared | CO2 | on request | >5 | ZSIC02/EX | 5 mesi/months | 5% Vol |
TS593IE | Infrared | C2H2 | on request | >5 | ZSI02/EX | 5 mesi/months | 0÷100% LEL |
TS593IX | Infrared | C3H8 | on request | >5 | ZSI01/EX | 5 mesi/months | 0÷100% LEL |
TS593IM | Infrared | CH4 | on request | >5 | ZSK01/EX | 5 mesi/months | 0÷100% LEL |
TS593IX | Infrared | **different** | on request | >5 | ZSI01/EX | 5 mesi/months | 0÷100% LEL |
TS593ECL | Electrochemical | CL | BO200 | 5 | ZSK02/EX | 5 mesi/months | 0÷20% LEL |