Produced by:
via Miglioli, 47 - 20054 Segrate (MI), Italy
Tel.+39 02 26922890
1872
TS293 Industrial gas detector, with replaceable cartridge sensor ATEX certified for Zone 1
The gas detectors in explosion-proof housing for use in potentially explosive atmospheres are Certificated CESI 03 ATEX 323 X extension n. 2.11 (31/04/2011) updating to EN IEC 60079-0:2018 and EN60079-1:2014 standards and characterized by the
following Ex marking (Directive 2014/34/EU):
* Archievable for Flammable gases, Toxic and Oxygen
* Can be equipped with sensible element: Catalytic, Pellistor, Electrochemical, Infrared
* Available with: 4-20mA output
* Auto get zero drift
All models are equipped with:
* Replaceable cartridge sensor
* Pre-calibrated cartridges
* Automatic Zero in air simplified using “F1” and “F2” keys
* Automatic calibration simplified by “F1” ed “F2” keys
* Made with 3 microprocessors
* Polarized terminals
* Housing II 2 G Ex db IIC T6 Gb
* Certification CESI 03 ATEX 323 X
Ex marking : II 2G Ex d IIC T6 Gb
No. 1 linear 4÷20 mA current output
Terminals plug-in type
-
Instructions TS293K for flammable gases - -catalytic
-
Instructions TS293E Electrochemical for toxic gases
-
Instructions TS293EO Electrochemical for oxygene
-
Instructions TS293IM TS293IG Infrared for flammable gases
-
Instructions TS293IC2 Infrared for CO2
-
Instructions TS293P for flammable gases - Pellistor
-
Instructions TS293PX for flammable gases - Pellistor
-
CESI ATEX Certificate for SE138 TS293
-
ATEX Safety instruction
-
Certificate CESI 04 ATEX 099Q Quality Assurance Notification TECNOCONTROL
TS293 Industrial gas detector, with replaceable cartridge sensor ATEX certified for Zone 1
images/zoo/TS293_atex.png
<p>The gas detectors in explosion-proof housing for use in potentially explosive atmospheres are Certificated CESI 03 ATEX 323 X extension n. 2.11 (31/04/2011) updating to EN IEC 60079-0:2018 and EN60079-1:2014 standards and characterized by the<br />following Ex marking (Directive 2014/34/EU):</p>
<p>* Archievable for Flammable gases, Toxic and Oxygen<br />* Can be equipped with sensible element: Catalytic, Pellistor, Electrochemical, Infrared<br />* Available with: 4-20mA output<br />* Auto get zero drift</p>
<p>All models are equipped with:<br />* Replaceable cartridge sensor<br />* Pre-calibrated cartridges<br />* Automatic Zero in air simplified using “F1” and “F2” keys<br />* Automatic calibration simplified by “F1” ed “F2” keys<br />* Made with 3 microprocessors<br />* Polarized terminals<br />* Housing II 2 G Ex db IIC T6 Gb<br />* Certification CESI 03 ATEX 323 X</p>
<p> </p>
<p>Ex marking : II 2G Ex d IIC T6 Gb<br />No. 1 linear 4÷20 mA current output<br />Terminals plug-in type</p>
<p><img src="images/zoo/ts293-schema.jpg" alt="" width="50%" height="NaN" /></p>
Industrial gas detectors
// Code example
<div id="myid" class="myclass" hidden>
Lorem ipsum <strong>dolor</strong> sit amet, consectetur adipiscing elit.
</div>
Type | Sensors | Gas | cylinder | Average Time | Cartridge | Maximun storage time | measuring range |
---|---|---|---|---|---|---|---|
TS293KM | Catalitico | Metano | BO200 | 5 | ZSK02/EX | 5 | 0÷20% LEL |
TS293KG | Catalitico | GPL | BO200 | 5 | ZSK02/EX | 5 | 0÷20% LEL |
TS293KI | Catalitico | Idrogeno | BO200 | 5 | ZSK02/EX | 5 | 0÷20% LEL |
TS293KB | Catalitico | Benzina | BO200 | 5 | ZSK04/EX | 5 | 0÷20% LEL |
TS293PM | Pellistor | Metano | BO200 | 5 | ZSP05/EX | 5 | 0÷100% LEL |
TS293PG | Pellistor | GPL | BO200 | 5 | ZSP05/EX | 5 | 0÷100% LEL |
TS293PI | Pellistor | Idrogeno | BO200 | 5 | ZSP05/EX | 5 | 0÷100% LEL |
TS293PB | Pellistor | Benzina | BO200 | 5 | ZSP05/EX | 5 | 0÷100% LEL |
TS293PX | Pellistor | **Vari** | BO200 | 5 | ZSP05/EX | 5 | 0÷100% LEL |
TS293EA | Elettrochimico | Ammoniaca | a richiesta | 3 | ZSEA1/EX | 5 | 0÷300 ppm |
TS293EC-S | Elettrochimico | Monossido di carbonio | BO210 | 2 | ZSEC1/EX | 1 mesi | 0÷300 ppm |
TS293EC-H | Elettrochimico | Monossido di carbonio | BO210 | 2 | ZSEC2/EX | 3 mesi | 0÷300 ppm |
TS293EH | Elettrochimico | Idr. solforato | BO009 | 2 | ZSEH1/EX | 3 mesi | 0÷100 ppm |
TS293EHCN | Elettrochimico | Acido Cianidrico | BO016 | 2 | ZSEH1/EX | 3 mesi | 0÷100 ppm |
TS293EN | Elettrochimico | Ossido Di Azoto | BO009 | 2 | ZSEN1/EX | 3 mesi | 0÷100 ppm |
TS293EN2 | Elettrochimico | Biossido di Azoto | a richiesta | 2 | ZSEN2/EX | 3 mesi | 0÷30 ppm |
TS293E0 | Elettrochimico | Ossigeno | a Richiesta | 2 | ZSEO1/EX | 3 mesi | 0÷25% Vol |
TS293E0 | Elettrochimico | Anidride Solforosa | a Richiesta | 2 | ZSES1/EX | 3 Mesi | 0÷20 ppm |
TS293EHCL | Elettrochimico | Acido Cloridrico | a Richiesta | 2 | ZSEHCL/EX | 3 mesi | 0÷30 ppm |
TS293IC2 | Infrared | Anidride Carbonica | on request | >5 | ZSIC01/EX | 5 | 0÷5% VOL |
TS293IC2-H | Infrared | Anidride Carbonica | on request | >5 | ZSIC02/EX | 5 | 0÷5000 ppm |
TS293IE | Infrared | Acetilene | on request | >5 | ZSI02/EX | 5 | 0÷100% LEL |
TS293IG | Infrared | Propano | on request | >5 | ZSI01/EX | 5 | 0÷100% LEL |
TS293IM | Infrared | Metano | on request | >5 | ZSK01/EX | 5 | 0÷100% LEL |
TS293IX | Infrared | **vari** | on request | >5 | ZSI01/EX | 5 | 0÷100% LEL |